      1. Used for emergency shut-off valve pneumatic ammonia

        Dateline:2014-11-30    Hits:

        A, use and performance specification:

        This valve is a safety protective valve, installed in the liquefied petroleum gas (gas),liquid and gas pipeline, and supporting the use of long distance gas source, the use of gas control valve open close, so that occurs in a pipe or tank large leak even when the fire started, the fast manual so that the gas source pressure relief, or high temperature is greater than or equal to 75%%p5C%%D when the fusible alloy melts,while the cylinder automatic pressure relief, rapid closure of the valve and the leakage stopping, play the role of security protection.

        The working principle, control two

        The valve air entrance installed by a two position three way electromagnetic valve,electrical appliances using a remote console control valve switch.

        1 gas leak alarm alarm energized, solenoid valve exhaust, the valve is automatically closed.

        2 manual control solenoid valve (press the red clip) exhaust, the valve is automatically closed.

        Three: the main performance specifications

        The pressure cylinder working pressure rating of 2.5/4.0Mpa is less than or equal to 2.0Mpa

        Using the temperature of -40~+80 DEG C cylinder using the medium nitrogen ` dry air

        Using the medium of natural gas, liquefied gas, the closing time of plus or minus 70 DEG C melting

        Closing time less than 5 seconds to open the cylinder pressure is greater than or equal to 0.5-0.7Mpa

        Four main parts: material

        Parts name material

        The valve body valve cover of carbon steels

        Cylinder, piston nodular cast iron

        O type sealing ring, Sichuan PTFE, NBR

        Spring 50CrVA (Dan Huanggang)

        Pneumatic emergency cut off valve installation size

        The maximum flow DN-JIS L: L / Max.FIoW/min

        Mm in

        251 "160160

        32 1-1/4 "200400

        40 1-1/2 "200400

        502 "240640

        803 "2831600

        1004 "3052500

        1506 "4033300

        2008 "5025900


        The previous product:Bellows gate valve
        The next product:Pneumatic diaphragm control valve

        手機網(wǎng)站

        亚洲精品无码不卡在线_夜夜添无码一区二区三区_国产亚洲日韩网曝_亚洲精品美女久久久
        <noframes id="tmfas"><bdo id="tmfas"></bdo>
        <strong id="tmfas"><pre id="tmfas"><xmp id="tmfas"></xmp></pre></strong>
      2. <strong id="tmfas"></strong>

        <small id="tmfas"><del id="tmfas"></del></small>